Training courses

Kernel and Embedded Linux

Bootlin training courses

Embedded Linux, kernel,
Yocto Project, Buildroot, real-time,
graphics, boot time, debugging...

Bootlin logo

Elixir Cross Referencer

   1
   2
   3
   4
   5
   6
   7
   8
   9
  10
  11
  12
  13
  14
  15
  16
  17
  18
  19
  20
  21
  22
  23
  24
  25
  26
  27
  28
  29
  30
  31
  32
  33
  34
  35
  36
  37
  38
  39
  40
  41
  42
  43
  44
  45
  46
  47
  48
  49
  50
  51
  52
  53
  54
  55
  56
  57
  58
  59
  60
  61
  62
  63
  64
  65
  66
  67
  68
  69
  70
  71
  72
  73
  74
  75
  76
  77
  78
  79
  80
  81
  82
  83
  84
  85
  86
  87
  88
  89
  90
  91
  92
  93
  94
  95
  96
  97
  98
  99
 100
 101
 102
 103
 104
 105
 106
 107
 108
 109
 110
 111
 112
 113
 114
 115
 116
 117
 118
 119
 120
 121
 122
 123
 124
 125
 126
 127
 128
 129
 130
 131
 132
 133
 134
 135
 136
 137
 138
 139
 140
 141
 142
 143
 144
 145
 146
 147
 148
 149
 150
 151
 152
 153
 154
 155
 156
 157
 158
 159
 160
 161
 162
 163
 164
 165
 166
 167
 168
 169
 170
 171
 172
 173
 174
 175
 176
 177
 178
 179
 180
 181
 182
 183
 184
 185
 186
 187
 188
 189
 190
 191
 192
 193
 194
 195
 196
 197
 198
 199
 200
 201
 202
 203
 204
 205
 206
 207
 208
 209
 210
 211
 212
 213
 214
 215
 216
 217
 218
 219
 220
 221
 222
 223
 224
 225
 226
 227
 228
 229
 230
 231
 232
 233
 234
 235
 236
 237
 238
 239
 240
 241
 242
 243
 244
 245
 246
 247
 248
 249
 250
 251
 252
 253
 254
 255
 256
 257
 258
 259
 260
 261
 262
 263
 264
 265
 266
 267
 268
 269
 270
 271
 272
 273
 274
 275
 276
 277
 278
 279
 280
 281
 282
 283
 284
 285
 286
 287
 288
 289
 290
 291
 292
 293
 294
 295
 296
 297
 298
 299
 300
 301
 302
 303
 304
 305
 306
 307
 308
 309
 310
 311
 312
 313
 314
 315
 316
 317
 318
 319
 320
 321
 322
 323
 324
 325
 326
 327
 328
 329
 330
 331
 332
 333
 334
 335
 336
 337
 338
 339
 340
 341
 342
 343
 344
 345
 346
 347
 348
 349
 350
 351
 352
 353
 354
 355
 356
 357
 358
 359
 360
 361
 362
 363
 364
 365
 366
 367
 368
 369
 370
 371
 372
 373
 374
 375
 376
 377
 378
 379
 380
 381
 382
 383
 384
 385
 386
 387
 388
 389
 390
 391
 392
 393
 394
 395
 396
 397
 398
 399
 400
 401
 402
 403
 404
 405
 406
 407
 408
 409
 410
 411
 412
 413
 414
 415
 416
 417
 418
 419
 420
 421
 422
 423
 424
 425
 426
 427
 428
 429
 430
 431
 432
 433
 434
 435
 436
 437
 438
 439
 440
 441
 442
 443
 444
 445
 446
 447
 448
 449
 450
 451
 452
 453
 454
 455
 456
 457
 458
 459
 460
 461
 462
 463
 464
 465
 466
 467
 468
 469
 470
 471
 472
 473
 474
 475
 476
 477
 478
 479
 480
 481
 482
 483
 484
 485
 486
 487
 488
 489
 490
 491
 492
 493
 494
 495
 496
 497
 498
 499
 500
 501
 502
 503
 504
 505
 506
 507
 508
 509
 510
 511
 512
 513
 514
 515
 516
 517
 518
 519
 520
 521
 522
 523
 524
 525
 526
 527
 528
 529
 530
 531
 532
 533
 534
 535
 536
 537
 538
 539
 540
 541
 542
 543
 544
 545
 546
 547
 548
 549
 550
 551
 552
 553
 554
 555
 556
 557
 558
 559
 560
 561
 562
 563
 564
 565
 566
 567
 568
 569
 570
 571
 572
 573
 574
 575
 576
 577
 578
 579
 580
 581
 582
 583
 584
 585
 586
 587
 588
 589
 590
 591
 592
 593
 594
 595
 596
 597
 598
 599
 600
 601
 602
 603
 604
 605
 606
 607
 608
 609
 610
 611
 612
 613
 614
 615
 616
 617
 618
 619
 620
 621
 622
 623
 624
 625
 626
 627
 628
 629
 630
 631
 632
 633
 634
 635
 636
 637
 638
 639
 640
 641
 642
 643
 644
 645
 646
 647
 648
 649
 650
 651
 652
 653
 654
 655
 656
 657
 658
 659
 660
 661
 662
 663
 664
 665
 666
 667
 668
 669
 670
 671
 672
 673
 674
 675
 676
 677
 678
 679
 680
 681
 682
 683
 684
 685
 686
 687
 688
 689
 690
 691
 692
 693
 694
 695
 696
 697
 698
 699
 700
 701
 702
 703
 704
 705
 706
 707
 708
 709
 710
 711
 712
 713
 714
 715
 716
 717
 718
 719
 720
 721
 722
 723
 724
 725
 726
 727
 728
 729
 730
 731
 732
 733
 734
 735
 736
 737
 738
 739
 740
 741
 742
 743
 744
 745
 746
 747
 748
 749
 750
 751
 752
 753
 754
 755
 756
 757
 758
 759
 760
 761
 762
 763
 764
 765
 766
 767
 768
 769
 770
 771
 772
 773
 774
 775
 776
 777
 778
 779
 780
 781
 782
 783
 784
 785
 786
 787
 788
 789
 790
 791
 792
 793
 794
 795
 796
 797
 798
 799
 800
 801
 802
 803
 804
 805
 806
 807
 808
 809
 810
 811
 812
 813
 814
 815
 816
 817
 818
 819
 820
 821
 822
 823
 824
 825
 826
 827
 828
 829
 830
 831
 832
 833
 834
 835
 836
 837
 838
 839
 840
 841
 842
 843
 844
 845
 846
 847
 848
 849
 850
 851
 852
 853
 854
 855
 856
 857
 858
 859
 860
 861
 862
 863
 864
 865
 866
 867
 868
 869
 870
 871
 872
 873
 874
 875
 876
 877
 878
 879
 880
 881
 882
 883
 884
 885
 886
 887
 888
 889
 890
 891
 892
 893
 894
 895
 896
 897
 898
 899
 900
 901
 902
 903
 904
 905
 906
 907
 908
 909
 910
 911
 912
 913
 914
 915
 916
 917
 918
 919
 920
 921
 922
 923
 924
 925
 926
 927
 928
 929
 930
 931
 932
 933
 934
 935
 936
 937
 938
 939
 940
 941
 942
 943
 944
 945
 946
 947
 948
 949
 950
 951
 952
 953
 954
 955
 956
 957
 958
 959
 960
 961
 962
 963
 964
 965
 966
 967
 968
 969
 970
 971
 972
 973
 974
 975
 976
 977
 978
 979
 980
 981
 982
 983
 984
 985
 986
 987
 988
 989
 990
 991
 992
 993
 994
 995
 996
 997
 998
 999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
.\"
.\" Copyright (c) 2003 Silicon Graphics International Corp.
.\" Copyright (c) 2015-2020 Alexander Motin <mav@FreeBSD.org>
.\" Copyright (c) 2018 Marcelo Araujo <araujo@FreeBSD.org>
.\" All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions, and the following disclaimer,
.\"    without modification.
.\" 2. Redistributions in binary form must reproduce at minimum a disclaimer
.\"    substantially similar to the "NO WARRANTY" disclaimer below
.\"    ("Disclaimer") and any redistribution must be conditioned upon
.\"    including a substantially similar Disclaimer requirement for further
.\"    binary redistribution.
.\"
.\" NO WARRANTY
.\" THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
.\" "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
.\" LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR
.\" A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
.\" HOLDERS OR CONTRIBUTORS BE LIABLE FOR SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
.\" STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING
.\" IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
.\" POSSIBILITY OF SUCH DAMAGES.
.\"
.\" ctladm utility man page.
.\"
.\" Author: Ken Merry <ken@FreeBSD.org>
.\"
.\" $Id: //depot/users/kenm/FreeBSD-test2/usr.sbin/ctladm/ctladm.8#3 $
.\" $FreeBSD$
.\"
.Dd August 6, 2020
.Dt CTLADM 8
.Os
.Sh NAME
.Nm ctladm
.Nd CAM Target Layer control utility
.Sh SYNOPSIS
.Nm
.Aq Ar command
.Op lun
.Op generic args
.Op command args
.Nm
.Ic tur
.Aq lun
.Op general options
.Nm
.Ic inquiry
.Aq lun
.Op general options
.Nm
.Ic reqsense
.Aq lun
.Op general options
.Nm
.Ic reportluns
.Aq lun
.Op general options
.Nm
.Ic read
.Aq lun
.Op general options
.Aq Fl l Ar lba
.Aq Fl d Ar datalen
.Aq Fl f Ar file|-
.Aq Fl b Ar blocksize_bytes
.Op Fl c Ar cdbsize
.Op Fl N
.Nm
.Ic write
.Aq lun
.Op general options
.Aq Fl l Ar lba
.Aq Fl d Ar datalen
.Aq Fl f Ar file|-
.Aq Fl b Ar blocksize_bytes
.Op Fl c Ar cdbsize
.Op Fl N
.Nm
.Ic readcap
.Aq lun
.Op general options
.Op Fl c Ar cdbsize
.Nm
.Ic modesense
.Aq lun
.Aq Fl m Ar page | Fl l
.Op Fl P Ar pc
.Op Fl d
.Op Fl S Ar subpage
.Op Fl c Ar size
.Nm
.Ic start
.Aq lun
.Op general options
.Op Fl i
.Op Fl o
.Nm
.Ic stop
.Aq lun
.Op general options
.Op Fl i
.Op Fl o
.Nm
.Ic synccache
.Aq lun
.Op general options
.Op Fl l Ar lba
.Op Fl b Ar blockcount
.Op Fl r
.Op Fl i
.Op Fl c Ar cdbsize
.Nm
.Ic lunlist
.Nm
.Ic delay
.Aq lun
.Aq Fl l Ar datamove|done
.Aq Fl t Ar secs
.Op Fl T Ar oneshot|cont
.Nm
.Ic inject
.Aq Fl i Ar action
.Aq Fl p Ar pattern
.Op Fl r Ar lba,len
.Op Fl s Ar len fmt Op Ar args
.Op Fl c
.Op Fl d Ar delete_id
.Nm
.Ic create
.Aq Fl b Ar backend
.Op Fl B Ar blocksize
.Op Fl d Ar device_id
.Op Fl l Ar lun_id
.Op Fl o Ar name=value
.Op Fl s Ar size_bytes
.Op Fl S Ar serial_num
.Op Fl t Ar device_type
.Nm
.Ic remove
.Aq Fl b Ar backend
.Aq Fl l Ar lun_id
.Op Fl o Ar name=value
.Nm
.Ic modify
.Aq Fl b Ar backend
.Aq Fl l Ar lun_id
.Op Fl o Ar name=value
.Aq Fl s Ar size_bytes
.Nm
.Ic devlist
.Op Fl b Ar backend
.Op Fl v
.Op Fl x
.Nm
.Ic port
.Op Fl c
.Op Fl o Ar on|off
.Op Fl w Ar wwpn
.Op Fl W Ar wwnn
.Op Fl O Ar pp|vp
.Op Fl p Ar targ_port
.Op Fl r Ar targ_port
.Op Fl t Ar fe_type
.Nm
.Ic portlist
.Op Fl f Ar frontend
.Op Fl i
.Op Fl l
.Op Fl p Ar targ_port
.Op Fl q
.Op Fl v
.Op Fl x
.Nm
.Ic lunmap
.Aq Fl p Ar targ_port
.Op Fl l Ar pLUN
.Op Fl L Ar cLUN
.Nm
.Ic dumpooa
.Nm
.Ic dumpstructs
.Nm
.Ic islist
.Op Fl v
.Op Fl x
.Nm
.Ic islogout
.Aq Fl a | Fl c Ar connection-id | Fl i Ar name | Fl p Ar portal
.Nm
.Ic isterminate
.Aq Fl a | Fl c Ar connection-id | Fl i Ar name | Fl p Ar portal
.Nm
.Ic help
.Sh DESCRIPTION
The
.Nm
utility is designed to provide a way to access and control the CAM Target
Layer (CTL).
It provides a way to send
.Tn SCSI
commands to the CTL layer, and also provides
some meta-commands that utilize
.Tn SCSI
commands.
(For instance, the
.Ic lunlist
command is implemented using the
.Tn SCSI
REPORT LUNS and INQUIRY commands.)
.Pp
The
.Nm
utility has a number of primary functions, many of which require a device
identifier.
The device identifier takes the following form:
.Bl -tag -width 14n
.It lun
Specify the LUN number to operate on.
.El
Many of the primary functions of the
.Nm
utility take the following optional arguments:
.Bl -tag -width 10n
.It Fl C Ar retries
Specify the number of times to retry a command in the event of failure.
.It Fl D Ar device
Specify the device to open.
This allows opening a device other than the default device,
.Pa /dev/cam/ctl ,
to be opened for sending commands.
.It Fl I Ar id
Specify the initiator number to use.
By default,
.Nm
will use 7 as the initiator number.
.El
.Pp
Primary commands:
.Bl -tag -width 11n
.It Ic tur
Send the
.Tn SCSI
TEST UNIT READY command to the device and report whether or not it is
ready.
.It Ic inquiry
Send the
.Tn SCSI
INQUIRY command to the device and display some of the returned inquiry
data.
.It Ic reqsense
Send the
.Tn SCSI
REQUEST SENSE command to the device and display the returned sense
information.
.It Ic reportluns
Send the
.Tn SCSI
REPORT LUNS command to the device and display supported LUNs.
.It Ic read
Send a
.Tn SCSI
READ command to the device, and write the requested data to a file or
stdout.
.Bl -tag -width 12n
.It Fl l Ar lba
Specify the starting Logical Block Address for the READ.
This can be specified in decimal, octal (starting with 0),
hexadecimal (starting with 0x) or any other base supported by
.Xr strtoull 3 .
.It Fl d Ar datalen
Specify the length, in 512 byte blocks, of the READ request.
.It Fl f Ar file
Specify the destination for the data read by the READ command.
Either a filename or
.Sq -
for stdout may be specified.
.It Fl c Ar cdbsize
Specify the minimum
.Tn SCSI
CDB (Command Data Block) size to be used for the READ request.
Allowable values are 6, 10, 12 and 16.
Depending upon the LBA and amount of data requested, a larger CDB
size may be used to satisfy the request.  (e.g., for LBAs above 0xffffffff,
READ(16) must be used to satisfy the request.)
.It Fl b Ar blocksize
Specify the blocksize of the underlying
.Tn SCSI
device, so the transfer length
can be calculated accurately.
The blocksize can be obtained via the
.Tn SCSI
READ CAPACITY command.
.It Fl N
Do not copy data to
.Nm
from the kernel when doing a read, just execute the command without copying
data.
This is to be used for performance testing.
.El
.It Ic write
Read data from a file or stdin, and write the data to the device using the
.Tn SCSI
WRITE command.
.Bl -tag -width 12n
.It Fl l Ar lba
Specify the starting Logical Block Address for the WRITE.
This can be specified in decimal, octal (starting with 0), hexadecimal
(starting with 0x) or any other base supported by
.Xr strtoull 3 .
.It Fl d Ar atalen
Specify the length, in 512 byte blocks, of the WRITE request.
.It Fl f Ar file
Specify the source for the data to be written by the WRITE command.
Either a filename or
.Sq -
for stdin may be specified.
.It Fl c Ar cdbsize
Specify the minimum
.Tn SCSI
CDB (Command Data Block) size to be used for the READ request.
Allowable values are 6, 10, 12 and 16.
Depending upon the LBA and amount of data requested, a larger CDB size
may be used to satisfy the request.  (e.g., for LBAs above 0xffffffff, READ(16)
must be used to satisfy the request.)
.It Fl b Ar blocksize
Specify the blocksize of the underlying
.Tn SCSI
device, so the transfer length
can be calculated accurately.
The blocksize can be obtained via the
.Tn SCSI
READ CAPACITY command.
.It Fl N
Do not copy data to
.Nm
to the kernel when doing a write, just execute the command without copying
data.
This is to be used for performance testing.
.El
.It Ic readcap
Send the
.Tn SCSI
READ CAPACITY command to the device and display the device size and device
block size.
By default, READ CAPACITY(10) is used.
If the device returns a maximum LBA of 0xffffffff, however,
.Nm
will automatically issue a READ CAPACITY(16), which is implemented as a
service action of the SERVICE ACTION IN(16) opcode.
The user can specify the minimum CDB size with the
.Fl c
argument.
Valid values for the
.Fl c
option are 10 and 16.
If a 10 byte CDB is specified, the request will be automatically reissued
with a 16 byte CDB if the maximum LBA returned is 0xffffffff.
.It Ic modesense
Send a
.Tn SCSI
MODE SENSE command to the device, and display the requested mode page(s) or
page list.
.Bl -tag -width 10n
.It Fl m Ar page
Specify the mode page to display.
This option and the
.Fl l
option are mutually exclusive.
One of the two must be specified, though.
Mode page numbers may be specified in decimal or hexadecimal.
.It Fl l
Request that the list of mode pages supported by the device be returned.
This option and the
.Fl m
option are mutually exclusive.
One of the two must be specified, though.
.It Fl P Ar pc
Specify the mode page control value.
Possible values are:
.Bl -tag -width 2n -compact
.It 0
Current values.
.It 1
Changeable value bitmask.
.It 2
Default values.
.It 3
Saved values.
.El
.It Fl d
Disable block descriptors when sending the mode sense request.
.It Fl S Ar subpage
Specify the subpage used with the mode sense request.
.It Fl c Ar cdbsize
Specify the CDB size used for the mode sense request.
Supported values are 6 and 10.
.El
.It Ic start
Send the
.Tn SCSI
START STOP UNIT command to the specified LUN with the start
bit set.
.Bl -tag -width 4n
.It Fl i
Set the immediate bit in the CDB.
Note that CTL does not support the immediate bit, so this is primarily
useful for making sure that CTL returns the proper error.
.El
.It Ic stop
Send the
.Tn SCSI
START STOP UNIT command to the specified LUN with the start
bit cleared.
We use an ordered tag to stop the LUN, so we can guarantee that all pending
I/O executes before it is stopped.
(CTL guarantees this anyway, but
.Nm
sends an ordered tag for completeness.)
.Bl -tag -width 4n
.It Fl i
Set the immediate bit in the CDB.
Note that CTL does not support the immediate bit, so this is primarily
useful for making sure that CTL returns the proper error.
.El
.It Ic synccache
Send the
.Tn SCSI
SYNCHRONIZE CACHE command to the device.
By default, SYNCHRONIZE CACHE(10) is used.
If the specified starting LBA is greater than 0xffffffff or the length is
greater than 0xffff, though, SYNCHRONIZE CACHE(16) will be used.
The 16 byte command will also be used if the user specifies a 16 byte CDB with the
.Fl c
argument.
.Bl -tag -width 14n
.It Fl l Ar lba
Specify the starting LBA of the cache region to synchronize.
This option is a no-op for CTL.
If you send a SYNCHRONIZE CACHE command, it will sync the cache for the entire LUN.
.It Fl b Ar blockcount
Specify the length of the cache region to synchronize.
This option is a no-op for CTL.
If you send a SYNCHRONIZE CACHE command, it will sync the cache for the entire LUN.
.It Fl r
Specify relative addressing for the starting LBA.
CTL does not support relative addressing, since it only works for linked commands,
and CTL does not support linked commands.
.It Fl i
Tell the target to return status immediately after issuing the SYNCHRONIZE CACHE
command rather than waiting for the cache to finish syncing.
CTL does not support this bit.
.It Fl c Ar cdbsize
Specify the minimum CDB size.
Valid values are 10 and 16 bytes.
.El
.It Ic lunlist
List all LUNs registered with CTL.
Because this command uses the ioctl port, it will only work when the FETDs
(Front End Target Drivers) are enabled.
This command is the equivalent of doing a REPORT LUNS on one LUN and then
an INQUIRY on each LUN in the system.
.It Ic delay
Delay commands at the given location.
There are two places where commands may be delayed currently: before data is transferred
.Pq Dq datamove
and just prior to sending status to the host
.Pq Dq done .
One of the two must be supplied as an argument to the
.Fl l
option.
The
.Fl t
option must also be specified.
.Bl -tag -width 12n
.It Fl l Ar delayloc
Delay command(s) at the specified location.
This can either be at the data movement stage (datamove) or prior to
command completion (done).
.It Fl t Ar delaytime
Delay command(s) for the specified number of seconds.
This must be specified.
If set to 0, it will clear out any previously set delay for this particular
location (datamove or done).
.It Fl T Ar delaytype
Specify the delay type.
By default, the
.Ic delay
option will delay the next command sent to the given LUN.
With the
.Fl T Ar cont
option, every command will be delayed by the specified period of time.
With the
.Fl T Ar oneshot
the next command sent to the given LUN will be delayed and all subsequent
commands will be completed normally.
This is the default.
.El
.It Ic inject
Inject the specified type of error for the LUN specified, when a command
that matches the given pattern is seen.
The sense data returned is in either fixed or descriptor format, depending
upon the status of the D_SENSE bit in the control mode page (page 0xa) for
the LUN.
.Pp
Errors are only injected for commands that have not already failed for
other reasons.
By default, only the first command matching the pattern specified is
returned with the supplied error.
.Pp
If the
.Fl c
flag is specified, all commands matching the pattern will be returned with
the specified error until the error injection command is deleted with
.Fl d
flag.
.Bl -tag -width 17n
.It Fl i Ar action
Specify the error to return:
.Bl -tag -width 10n
.It aborted
Return the next matching command on the specified LUN with the sense key
ABORTED COMMAND (0x0b), and the ASC/ASCQ 0x45,0x00 ("Select or reselect
failure").
.It mediumerr
Return the next matching command on the specified LUN with the sense key
MEDIUM ERROR (0x03) and the ASC/ASCQ 0x11,0x00 ("Unrecovered read error") for
reads, or ASC/ASCQ 0x0c,0x02 ("Write error - auto reallocation failed")
for write errors.
.It ua
Return the next matching command on the specified LUN with the sense key
UNIT ATTENTION (0x06) and the ASC/ASCQ 0x29,0x00 ("POWER ON, RESET, OR BUS
DEVICE RESET OCCURRED").
.It custom
Return the next matching command on the specified LUN with the supplied
sense data.
The
.Fl s
argument must be specified.
.El
.It Fl p Ar pattern
Specify which commands should be returned with the given error.
.Bl -tag -width 10n
.It read
The error should apply to READ(6), READ(10), READ(12), READ(16), etc.
.It write
The error should apply to WRITE(6), WRITE(10), WRITE(12), WRITE(16), WRITE
AND VERIFY(10), etc.
.It rw
The error should apply to both read and write type commands.
.It readcap
The error should apply to READ CAPACITY(10) and READ CAPACITY(16) commands.
.It tur
The error should apply to TEST UNIT READY commands.
.It any
The error should apply to any command.
.El
.It Fl r Ar lba,len
Specify the starting lba and length of the range of LBAs which should
trigger an error.
This option is only applies when read and/or write patterns are specified.
If used with other command types, the error will never be triggered.
.It Fl s Ar len fmt Op Ar args
Specify the sense data that is to be returned for custom actions.
If the format is
.Sq - ,
len bytes of sense data will be read from standard input and written to the
sense buffer.
If len is longer than 252 bytes (the maximum allowable
.Tn SCSI
sense data length), it will be truncated to that length.
The sense data format is described in
.Xr cam_cdbparse 3 .
.It Fl c
The error injection should be persistent, instead of happening once.
Persistent errors must be deleted with the
.Fl d
argument.
.It Fl d Ar delete_id
Delete the specified error injection serial number.
The serial number is returned when the error is injected.
.El
.It Ic port
Perform one of several CTL frontend port operations.
Either get a list of frontend ports
.Pq Fl l ,
turn one or more frontends on
or off
.Pq Fl o Ar on|off ,
or set the World Wide Node Name
.Pq Fl w Ar wwnn
or World Wide Port Name
.Pq Fl W Ar wwpn
for a given port.
One of
.Fl l ,
.Fl o ,
or
.Fl w
or
.Fl W
must be specified.
The WWNN and WWPN may both be specified at the same time, but cannot be
combined with enabling/disabling or listing ports.
.Bl -tag -width 12n
.It Fl c
Create new frontend port using free pp and vp=0.
.It Fl o Ar on|off
Turn the specified CTL frontend ports on or off.
If no port number or port type is specified, all ports are turned on or
off.
.It Fl O Ar pp|vp
Specify generic options on the ioctl frontend port.
At present, only pp and vp port numbers can be set.
.It Fl p Ar targ_port
Specify the frontend port number.
The port numbers can be found in the frontend port list.
.It Fl r
Remove port specified with
.Pq Fl p Ar targ_port .
.It Fl t Ar fe_type
Specify the frontend type.
Currently defined port types are
.Dq fc
(Fibre Channel),
.Dq scsi
(Parallel SCSI),
.Dq ioctl
(CTL ioctl interface),
and
.Dq internal
(CTL CAM SIM).
.It Fl w Ar wwnn
Set the World Wide Node Name for the given port.
The
.Fl n
argument must be specified, since this is only possible to implement on a
single port.
As a general rule, the WWNN should be the same across all ports on the
system.
.It Fl W Ar wwpn
Set the World Wide Port Name for the given port.
The
.Fl n
argument must be specified, since this is only possible to implement on a
single port.
As a general rule, the WWPN must be different for every port in the system.
.El
.It Ic portlist
List CTL frontend ports.
.Bl -tag -width 12n
.It Fl f Ar frontend
Specify the frontend type.
.It Fl i
Report target and connected initiators addresses.
.It Fl l
Report LUN mapping.
.It Fl p Ar targ_port
Specify the frontend port number.
.It Fl q
Omit the header in the port list output.
.It Fl v
Enable verbose output (report all port options).
.It Fl x
Output the port list in XML format.
.El
.It Ic lunmap
Change LUN mapping for specified port.
If both
.Ar pLUN
and
.Ar cLUN
are specified -- LUN will be mapped.
If
.Ar pLUN
is specified, but
.Ar cLUN
is not -- LUN will be unmapped.
If neither
.Ar pLUN
nor
.Ar cLUN
are specified -- LUN mapping will be disabled, exposing all CTL LUNs.
.Bl -tag -width 12n
.It Fl p Ar targ_port
Specify the frontend port number.
.It Fl l Ar pLUN
LUN number visible by specified port.
.It Fl L Ar cLUN
CTL LUN number.
.El
.It Ic dumpooa
Dump the OOA (Order Of Arrival) queue for each LUN registered with CTL.
.It Ic dumpstructs
Dump the CTL structures to the console.
.It Ic create
Create a new LUN.
The backend must be specified, and depending upon the backend requested,
some of the other options may be required.
If the LUN is created successfully, the LUN configuration will be
displayed.
If LUN creation fails, a message will be displayed describing the failure.
.Bl -tag -width 14n
.It Fl b Ar backend
The
.Fl b
flag is required.
This specifies the name backend to use when creating the LUN.
Examples are
.Dq ramdisk
and
.Dq block .
.It Fl B Ar blocksize
Specify the blocksize of the backend in bytes.
.It Fl d Ar device_id
Specify the LUN-associated string to use in the
.Tn SCSI
INQUIRY VPD page 0x83 data.
.It Fl l Ar lun_id
Request that a particular LUN number be assigned.
If the requested LUN number is not available, the request will fail.
.It Fl o Ar name=value
Specify a backend-specific name/value pair.
Multiple
.Fl o
arguments may be specified.
Refer to the backend documentation for arguments that may be used.
.It Fl s Ar size_bytes
Specify the size of the LUN in bytes.
Some backends may allow setting the size (e.g. the ramdisk backend) and for
others the size may be implicit (e.g. the block backend).
.It Fl S Ar serial_num
Specify the serial number to be used in the
.Tn SCSI
INQUIRY VPD page 0x80 data.
.It Fl t Ar device_type
Specify the numeric SCSI device type to use when creating the LUN.
If this flag is not used, the type of LUN created is backend-specific.
Not all LUN types are supported.
Currently CTL supports Direct Access (type 0), Processor (type 3)
and CD/DVD (type 5) LUNs.
The backend requested may or may not support all of the LUN types that CTL
supports.
.El
.It Ic remove
Remove a LUN.
The backend must be specified, and the LUN number must also be specified.
Backend-specific options may also be specified with the
.Fl o
flag.
.Bl -tag -width 14n
.It Fl b Ar backend
Specify the backend that owns the LUN to be removed.
Examples are
.Dq ramdisk
and
.Dq block .
.It Fl l Ar lun_id
Specify the LUN number to remove.
.It Fl o Ar name=value
Specify a backend-specific name/value pair.
Multiple
.Fl o
arguments may be specified.
Refer to the backend documentation for arguments that may be used.
.El
.It Ic modify
Modify a LUN size.
The backend, the LUN number, and the size must be specified.
.Bl -tag -width 14n
.It Fl b Ar backend
Specify the backend that owns the LUN to be modified.
Examples are
.Dq ramdisk
and
.Dq block .
.It Fl l Ar lun_id
Specify the LUN number to modify.
.It Fl o Ar name=value
Specify a backend-specific name/value pair.
Multiple
.Fl o
arguments may be specified.
Refer to the backend documentation for arguments that may be used.
.It Fl s Ar size_bytes
Specify the size of the LUN in bytes.
For the
.Dq block
backend, an
.Dq auto
keyword may be passed instead; this will make CTL use the size of backing
file or device.
.El
.It Ic devlist
Get a list of all configured LUNs.
This also includes the LUN size and blocksize, serial number and device ID.
.Bl -tag -width 11n
.It Fl b Ar backend
Specify the backend.
This restricts the LUN list to the named backend.
Examples are
.Dq ramdisk
and
.Dq block .
.It Fl v
Be verbose.
This will also display any backend-specific LUN attributes in addition to
the standard per-LUN information.
.It Fl x
Dump the raw XML.
The LUN list information from the kernel comes in XML format, and this
option allows the display of the raw XML data.
This option and the
.Fl v
and
.Fl b
options are mutually exclusive.
If you specify
.Fl x ,
the entire LUN database is displayed in XML format.
.El
.It Ic islist
Get a list of currently running iSCSI sessions.
This includes initiator and target names and the unique connection IDs.
.Bl -tag -width 11n
.It Fl v
Verbose mode.
.It Fl x
Dump the raw XML.
The sessions list information from the kernel comes in XML format, and this
option allows the display of the raw XML data.
.El
.It Ic islogout
Ask the initiator to log out iSCSI sessions matching criteria.
.Bl -tag -width 11n
.It Fl a
Log out all sessions.
.It Fl c
Specify connection ID.
.It Fl i
Specify initiator name.
.It Fl p
Specify initiator portal (hostname or IP address).
.El
.It Ic isterminate
Forcibly terminate iSCSI sessions matching criteria.
.Bl -tag -width 11n
.It Fl a
Terminate all sessions.
.It Fl c
Specify connection ID.
.It Fl i
Specify initiator name.
.It Fl p
Specify initiator portal (hostname or IP address).
.El
.It Ic help
Display
.Nm
usage information.
.El
.Sh OPTIONS
Number of additional configuration options may be specified for LUNs.
Some options are global, others are backend-specific.
.Pp
Global options:
.Bl -tag -width 12n
.It Va vendor
Specifies LUN vendor string up to 8 chars.
.It Va product
Specifies LUN product string up to 16 chars.
.It Va revision
Specifies LUN revision string up to 4 chars.
.It Va scsiname
Specifies LUN SCSI name string.
.It Va eui
Specifies LUN EUI-64 identifier.
.It Va naa
Specifies LUN NAA identifier.
.It Va uuid
Specifies LUN locally assigned RFC 4122 UUID identifier.
EUI, NAA or UUID identifier should be set to UNIQUE value to allow
EXTENDED COPY command access the LUN.
Non-unique LUN identifiers may lead to data corruption.
Some initiators may not support later introduced UUID identifiers.
.It Va ident_info
Specified LUN identification information (string or 0x + hex).
.It Va text_ident_info
Specified LUN text identification information (UTF-8 string).
.It Va ha_role
Setting to "primary" or "secondary" overrides default role of the node
in HA cluster, set by kern.cam.ctl.ha_role sysctl.
.It Va insecure_tpc
Setting to "on" allows EXTENDED COPY command sent to this LUN access
other LUNs on this host, not accessible otherwise.
This allows to offload copying between different iSCSI targets residing
on the same host in trusted environments.
.It Va readcache
Set to "off", disables read caching for the LUN, if supported by the backend.
.It Va readonly
Set to "on", blocks all media write operations to the LUN, reporting it
as write protected.
.It Va removable
Set to "on", makes LUN removable.
.It Va reordering
Set to "unrestricted", allows target to process commands with SIMPLE task
attribute in arbitrary order.
Any data integrity exposures related to command sequence order shall be
explicitly handled by the application client through the selection of
appropriate commands and task attributes.
The default value is "restricted".
It improves data integrity, but may introduce some additional delays.
.It Va serseq
Set to "on" to serialize consecutive reads/writes.
Set to "read" to serialize consecutive reads.
Set to "off" to allow them be issued in parallel.
Parallel issue of consecutive operations may confuse logic of the
backing file system, hurting performance; but it may improve performance
of backing stores without prefetch/write-back.
.It Va pblocksize
.It Va pblockoffset
Specify physical block size and offset of the device.
.It Va ublocksize
.It Va ublockoffset
Specify UNMAP block size and offset of the device.
.It Va rpm
Specifies medium rotation rate of the device: 0 -- not reported,
1 -- non-rotating (SSD), >1024 -- value in revolutions per minute.
.It Va formfactor
Specifies nominal form factor of the device: 0 -- not reported, 1 -- 5.25",
2 -- 3.5", 3 -- 2.5", 4 -- 1.8", 5 -- less then 1.8".
.It Va temperature
.It Va reftemperature
Specify current and reference (maximum) temperatures of the device.
.It Va provisioning_type
When UNMAP support is enabled, this option specifies provisioning type:
"resource", "thin" or "unknown".
Default value is "thin".
Logical units without UNMAP support are reported as fully provisioned.
.It Va unmap
Setting to "on" or "off" controls UNMAP support for the logical unit.
Default value is "on" if supported by the backend.
.It Va unmap_max_lba
.It Va unmap_max_descr
Specify maximum allowed number of LBAs and block descriptors per UNMAP
command to report in Block Limits VPD page.
.It Va write_same_max_lba
Specify maximum allowed number of LBAs per WRITE SAME command to report
in Block Limits VPD page.
.It Va avail-threshold
.It Va used-threshold
.It Va pool-avail-threshold
.It Va pool-used-threshold
Set per-LUN/-pool thin provisioning soft thresholds.
LUN will establish UNIT ATTENTION condition if its or pool available space
get below configured avail values, or its or pool used space get above
configured used values.
Pool thresholds are working only for ZVOL-backed LUNs.
.It Va writecache
Set to "off", disables write caching for the LUN, if supported by the backend.
.El
.Pp
Options specific for block backend:
.Bl -tag -width 12n
.It Va file
Specifies file or device name to use for backing store.
.It Va num_threads
Specifies number of backend threads to use for this LUN.
.El
.Pp
Options specific for ramdisk backend:
.Bl -tag -width 12n
.It Va capacity
Specifies capacity of backing store (maximum RAM for data).
The default value is zero, that disables backing store completely,
making all writes go to nowhere, while all reads return zeroes.
.El
.Sh EXAMPLES
.Pp
Send a
.Tn SCSI
TEST UNIT READY command to LUN 1.
.Pp
.Dl ctladm tur 1
.Pp
Display the list of mode pages supported by LUN 1.
.Pp
.Dl ctladm modesense 1 -l
.Pp
Display the saved version of the Control mode page (page 10) on LUN 0.
Disable fetching block descriptors, and use a 10 byte MODE SENSE command
instead of the default 6 byte command.
.Pp
.Dl ctladm modesense 0 -m 10 -P 3 -d -c 10
.Pp
Read the first 512 byte block from LUN 2 and dump it to the file
.Bd -literal
.Dl ctladm read 2 -l 0 -d 1 -b 512 -f - > foo
.Ed
.Pp
Read 10240 bytes from the file
.Pa /tmp/bar
and write it to LUN 3.
starting at LBA 0xff432140.
.Pp
.Bd -literal
.Dl ctladm write 3 -l 0xff432140 -d 20 -b 512 -f /tmp/bar
.Ed
.Pp
Create a LUN with the
.Dq fake
ramdisk as a backing store.
The LUN will claim to have a size of approximately 10 terabytes,
while having no real data store (all written data are lost).
.Pp
.Dl ctladm create -b ramdisk -s 10485760000000000
.Pp
Create a thin provisioned LUN with a ramdisk as a backing store.
The LUN will have maximal backing store capacity of 10 gigabytes,
while reporting size of 10 terabytes,
.Pp
.Dl ctladm create -b ramdisk -s 10T -o capacity=10G
.Pp
Create a LUN using the block backend, and specify the file
.Pa src/usr.sbin/ctladm/ctladm.8
as the backing store.
The size of the LUN will be derived from the size of the file.
.Pp
.Dl ctladm create -b block -o file=src/usr.sbin/ctladm/ctladm.8
.Pp
Create a LUN using the block backend, specify the file
.Pa src/usr.sbin/ctladm/ctladm.8
as the backing store, and specify the
.Tn SCSI
VPD page 0x80 and 0x83 serial number
.Fl ( S )
and device ID
.Fl ( d ) .
.Pp
.Dl ctladm create -b block -o file=src/usr.sbin/ctladm/ctladm.8 -S MYSERIAL321 -d MYDEVID123
.Pp
Use to specify generic options on ioctl frontend port, now it is
only possible to set pp and/or vp port number.
.Pp
.Dl ctladm port -c -O pp=11 -O vp=12
.Pp
Remove specified targ_port.
.Pp
.Dl ctladm port -r -p 4
.Pp
.Pp
Remove LUN 12, which is handled by the block backend, from the system.
.Pp
.Dl ctladm remove -b block -l 12
.Pp
List configured LUNs in the system, along with their backend and serial
number.
This works when the Front End Target Drivers are enabled or disabled.
.Pp
.Dl ctladm devlist
.Pp
List all LUNs in the system, along with their inquiry data and device type.
This only works when the FETDs are enabled, since the commands go through the
ioctl port.
.Pp
.Dl ctladm lunlist
.Pp
Inject a medium error on LUN 6 for every read that covers the first 512
blocks of the LUN.
.Pp
.Dl ctladm inject 6 -i mediumerr -p read -r 0,512 -c
.Pp
Inject a custom error on LUN 6 for the next TEST UNIT READY command only.
This will result in a sense key of NOT READY (0x02), and an ASC/ASCQ of
0x04,0x02 ("Logical unit not ready, initializing command required").
.Pp
.Bd -literal -offset indent
ctladm inject 6 -i custom -p tur -s 18 "f0 0 02 s12 04 02"
.Ed
.Sh SEE ALSO
.Xr cam 3 ,
.Xr cam_cdbparse 3 ,
.Xr cam 4 ,
.Xr ctl 4 ,
.Xr xpt 4 ,
.Xr camcontrol 8 ,
.Xr ctld 8 ,
.Xr ctlstat 8
.Sh HISTORY
The
.Nm
utility was originally written during the Winter/Spring of 2003 as an
interface to CTL.
.Sh AUTHORS
.An Ken Merry Aq Mt ken@FreeBSD.org