Training courses

Kernel and Embedded Linux

Bootlin training courses

Embedded Linux, kernel,
Yocto Project, Buildroot, real-time,
graphics, boot time, debugging...

Bootlin logo

Elixir Cross Referencer

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
.\"
.\" Copyright (c) 2002 M. Warner Losh <imp@FreeBSD.org>
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions and the following disclaimer.
.\" 2. The name of the author may not be used to endorse or promote products
.\"    derived from this software without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.\" The section on comments was taken from named.conf.5, which has the
.\" following copyright:
.\" Copyright (c) 1999-2000 by Internet Software Consortium
.\"
.\" Permission to use, copy, modify, and distribute this software for any
.\" purpose with or without fee is hereby granted, provided that the above
.\" copyright notice and this permission notice appear in all copies.
.\"
.\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
.\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
.\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
.\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
.\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
.\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
.\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
.\" SOFTWARE.
.\"
.Dd October 12, 2020
.Dt DEVD.CONF 5
.Os
.Sh NAME
.Nm devd.conf
.Nd configuration file for
.Xr devd 8
.Sh DESCRIPTION
.Ss General Syntax
A
.Xr devd 8
configuration consists of two general features, statements
and comments.
All statements end with a semicolon.
Many statements can contain substatements, which are also
terminated with a semicolon.
.Pp
The following statements are supported:
.Bl -tag -width ".Ic options"
.It Ic attach
Specifies various matching criteria and actions to perform when
a newly attached device matches said criteria.
.It Ic detach
Specifies various matching criteria and actions to perform when
a newly detached device matches said criteria.
.It Ic nomatch
Specifies various matching criteria and actions to perform when
no device driver currently loaded in the kernel claims a (new)
device.
.It Ic notify
Specifies various matching criteria and actions to perform when the kernel
sends an event notification to userland.
.It Ic options
Specifies various options and parameters for the operation of
.Xr devd 8 .
.El
.Pp
Statements may occur in any order in the configuration file, and may be
repeated as often as required.
Further details on the syntax and meaning of each statement and their
substatements are explained below.
.Pp
Each statement, except
.Ic options
has a priority (an arbitrary number) associated with it, where
.Ql 0
is defined as the lowest priority.
If two statements match the same event, only the action of the statement with
highest priority will be executed.
In this way generic statements can be overridden for devices or
notifications that require special attention.
.Pp
The general syntax of a statement is:
.Bd -literal -offset indent
statement priority {
	substatement "value";
	...
	substatement "value";
};
.Ed
.Ss Sub-statements
The following sub-statements are supported within the
.Ic options
statement.
.Bl -tag -width ".Ic directory"
.It Ic directory Qq Ar /some/path ;
Adds the given directory to the list of directories from which
.Xr devd 8
will read all files named "*.conf" as further
configuration files.
Any number of
.Ic directory
statements can be used.
.It Ic pid-file Qq Pa /var/run/devd.pid ;
Specifies PID file.
.It Ic set Ar regexp-name Qq Ar (some|regexp) ;
Creates a regular expression and assigns it to the variable
.Ar regexp-name .
The variable is available throughout the rest of
the configuration file.
If the string begins with
.Ql \&! ,
it matches if the regular expression formed by the rest of the string
does not match.
All regular expressions have an implicit
.Ql ^$
around them.
.El
.Pp
The following sub-statements are supported within the
.Ic attach
and
.Ic detach
statements.
.Bl -tag -width ".Ic directory"
.It Ic action Qq Ar command ;
Command to execute upon a successful match.
Example
.Dq Li "/etc/pccard_ether $device-name start" .
.It Ic class Qq Ar string ;
This is shorthand for
.Dq Ic match Qo Li class Qc Qq Ar string .
.It Ic device-name Qq string ;
This is shorthand for
.Dq Ic match Qo Li device-name Qc Qq Ar string .
This matches a device named
.Ar string ,
which is allowed to be a regular expression or a variable previously created
containing a regular expression.
The
.Dq Li device-name
variable
is available for later use with the
.Ic action
statement.
.It Ic match Qo Ar variable Qc Qq Ar value ;
Matches the content of
.Ar value
against
.Ar variable ;
the content of
.Ar value
may be a regular expression.
Not required during
.Ic attach
nor
.Ic detach
events since the
.Ic device-name
statement takes care of all device matching.
For a partial list of variables, see below.
.It Ic media-type Qq Ar string ;
For network devices,
.Ic media-type
will match devices that have the given media type.
Valid media types are:
.Dq Li Ethernet ,
.Dq Li Tokenring ,
.Dq Li FDDI ,
.Dq Li 802.11 ,
and
.Dq Li ATM .
.It Ic subdevice Qq Ar string ;
This is shorthand for
.Dq Ic match Qo Li subdevice Qc Qq Ar string .
.El
.Pp
The following sub-statements are supported within the
.Ic nomatch
statement.
.Bl -tag -width ".Ic directory"
.It Ic action Qq Ar command ;
Same as above.
.It Ic match Qo Ar variable Qc Qq Ar value ;
Matches the content of
.Ar value
against
.Ar variable ;
the content of
.Ar value
may be a regular expression.
For a partial list of variables, see below.
.El
.Pp
The following sub-statements are supported within the
.Ic notify
statement.
The
.Dq Li notify
variable is available inside this statement and contains, a value, depending
on which system and subsystem that delivered the event.
.Bl -tag -width ".Ic directory"
.It Ic action Qq Ar command ;
Command to execute upon a successful match.
Example
.Dq Li "/etc/rc.d/power_profile $notify" .
.It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
Any number of
.Ic match
statements can exist within a
.Ic notify
statement;
.Ar value
can be either a fixed string or a regular expression.
Below is a list of available systems, subsystems, and types.
.It Ic media-type Qq Ar string ;
See above.
.El
.Ss Variables that can be used with the match statement
A partial list of variables and their possible values that can be used together
with the
.Ic match
statement.
The variables are published by the bus based on characteristics of the device
that generated the event (for device events).
Variables for other classes of events are dependent on those events.
.Pp
.Bl -tag -width ".Li manufacturer" -compact
.It Ic Variable
.Ic Description
.It Li *
The entire message from the current event.
.It Li _
The entire message from the current event, after the initial type character.
.It Li timestamp
The time this event was processed, in seconds since 1970 dot fraction.
.It Li bus
Device name of parent bus.
.It Li cdev
Device node path if one is created by the
.Xr devfs 5
filesystem.
.It Li class
Device class.
.It Li comm
Executable name (kernel).
.It Li core
Path to core file (kernel).
.It Li device
Device ID.
.It Li devclass
Device Class (USB).
.It Li devsubclass
Device Sub-class (USB).
.It Li device-name
Name of attached/detached device.
.It Li endpoints
Endpoint count (USB).
.It Li function
Card functions.
.It Li interface
Interface ID (USB).
.It Li intclass
Interface Class (USB).
.It Li intprotocol
Interface Protocol (USB).
.It Li intsubclass
Interface Sub-class (USB).
.It Li jail
Jail name for the process triggering the rule (RCTL).
.It Li mode
Peripheral mode (USB).
.It Li notify
Match the value of the
.Dq Li notify
variable.
.It Li parent
Parent device.
.It Li pid
PID of the process triggering the rule (RCTL).
.It Li port
Hub port number (USB).
.It Li product
Product ID (USB).
.It Li release
Hardware revision (USB).
.It Li ruid
Real UID of the process triggering the rule (RCTL).
.It Li rule
Rule (RCTL).
.It Li sernum
Serial Number (USB).
.It Li slot
Card slot.
.It Li subvendor
Sub-vendor ID (PCI).
.It Li subdevice
Sub-device ID (PCI).
.It Li subsystem
Matches a subsystem of a system, see below.
.It Li system
Matches a system type, see below.
.It Li type
Type of notification, see below.
.It Li vendor
Vendor ID.
.El
.Ss Notify matching
A partial list of systems, subsystems, and types used within the
.Ic notify
mechanism.
.\"
.\" Please keep these tables sorted. Also, please use the same parameters
.\" for each of the tables so that things line up in columns nicely.
.\" Please do not omit the type column for notifiers that omit it.
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li ACPI Ta Ta Ta
Events related to the ACPI Subsystem.
.It Li ACPI Ta Li ACAD Ta Ta
AC line state ($notify=0x00 is offline, 0x01 is online).
.It Li ACPI Ta Li Button Ta Ta
Button state ($notify=0x00 is power, 0x01 is sleep).
.It Li ACPI Ta Li CMBAT Ta Ta
Battery events.
.It Li ACPI Ta Li Dock Ta Ta
Dock state ($notify=0x00 is undocked, 0x01 is docked).
.It Li ACPI Ta Li Lid Ta Ta
Lid state ($notify=0x00 is closed, 0x01 is open).
.It Li ACPI Ta Li PROCESSOR Ta Ta
Processor state/configuration ($notify=0x81 is a change in available Cx states).
.It Li ACPI Ta Li Resume Ta Ta
Resume notification.
.It Li ACPI Ta Li Suspend Ta Ta
Suspend notification.
.It Li ACPI Ta Li Thermal Ta Ta
Thermal zone events.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li AEON Ta Li power Ta Li press Ta
The power button on an Amiga has been pressed.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li CAM Ta Ta Ta
Events related to the
.Xr cam 4
system.
.It Li CAM Ta Li periph Ta Ta
Events related to peripheral devices.
.It Li CAM Ta Li periph Ta Li error Ta
Generic errors.
.It Li CAM Ta Li periph Ta Li timeout Ta
Command timeouts.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li CARP Ta Ta Ta
Events related to the
.Xr carp 4
protocol.
.It CARP Ta Ar vhid@inet Ta Ta
The
.Dq subsystem
contains the actual CARP vhid and the name of the network interface
on which the event took place.
.It CARP Ta Ar vhid@inet Ta MASTER Ta
Node become the master for a virtual host.
.It CARP Ta Ar vhid@inet Ta BACKUP Ta
Node become the backup for a virtual host.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li coretemp Ta Ta Ta
Events related to the
.Xr coretemp 4
device.
.It Li coretemp Ta Li Thermal Ta Ta
Notification that the CPU core has reached critical temperature.
.It Li coretemp Ta Li Thermal Ta Li temperature Ta
String containing the temperature of the core that has become too hot.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li DEVFS
.It Li DEVFS Ta Li CDEV Ta Li CREATE Ta
The
.Xr devfs 5
node is created.
.It Li DEVFS Ta Li CDEV Ta Li DESTROY Ta
The
.Xr devfs 5
node is destroyed.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li ETHERNET Ta Ar inet Ta IFATTACH Ta
Notification when the default VNET instance of the
.Ar inet
interface is attached.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li GEOM Ta Ta Ta
Events related to the
.Xr geom 4
framework.
The difference compared to
.Li DEVFS
is that
.Li GEOM
only includes disk-like devices.
.It Li GEOM Ta Li DEV Ta Li CREATE Ta
A
.Xr geom 4
provider is created.
.It Li GEOM Ta Li DEV Ta Li DESTROY Ta
A
.Xr geom 4
provider is destroyed.
.It Li GEOM Ta Li DEV Ta Li GEOM::physpath Ta
The physical path of a device has changed.
.It Li GEOM Ta Li DEV Ta Li GEOM::rotation_rate Ta
The rotation rate of the disk has changed.
.It Li GEOM Ta Li DEV Ta Li MEDIACHANGE Ta
Physical media has changed.
.It Li GEOM Ta Li DEV Ta Li SIZECHANGE Ta
A
.Xr geom 4
provider size has changed.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li IFNET
.It Li IFNET Ta Ar inet Ta Ta
The
.Dq subsystem
is the actual name of the network interface on which the event
took place.
.It Li IFNET Ta Ar inet Ta Li LINK_UP Ta
Carrier status changed to UP.
.It Li IFNET Ta Ar inet Ta Li LINK_DOWN Ta
Carrier status changed to DOWN.
.It Li IFNET Ta Ar inet Ta Li ATTACH Ta
The network interface is attached to the system.
.It Li IFNET Ta Ar inet Ta Li DETACH Ta
The network interface is detached from the system.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li kern Ta Li power Ta Li resume Ta
Notification that the system has woken from the suspended state.
Note: this notification is deprecated and will be removed in
.Fx 14.0 .
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li kernel Ta Li signal Ta Li coredump Ta
Notification that a process has crashed and dumped core.
.It Li kernel Ta Li power Ta Li resume Ta
Notification that the system has woken from the suspended state.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li PMU Ta Ta Ta
Notification of events from various types of Power Management Units.
.It Li PMU Ta Li "AC" Ta Ta
Notifications of AC power related events.
.It Li PMU Ta Li "AC" Ta Li overvoltage Ta
An over-voltage condition was detected on the AC power line.
.It Li PMU Ta Li "AC" Ta Li plugged Ta
Power has been applied to the AC power line.
.It Li PMU Ta Li "AC" Ta Li unplugged Ta
Power has been removed from the AC power line.
.It Li PMU Ta Li Battery Ta Ta
.It Li PMU Ta Li Battery Ta absent Ta
Battery is no longer absent.
.It Li PMU Ta Li Battery Ta charged Ta
The battery has become charged.
.It Li PMU Ta Li Battery Ta charging Ta
The battery has started charging.
.It Li PMU Ta Li Battery Ta disconnected Ta
The battery has been disconnected.
.It Li PMU Ta Li Battery Ta high-temp Ta
The battery reported a temperature over the limit.
.It Li PMU Ta Li Battery Ta low-temp Ta
The battery reported a temperature under the limit.
.It Li PMU Ta Li Battery Ta plugged Ta
The battery has become plugged (eg connected).
.It Li PMU Ta Li Battery Ta shutdown-threshold Ta
The power in the battery has fallen below the shutdown threshold.
.It Li PMU Ta Li Battery Ta warning-threshold Ta
The power in the battery has fallen below the warn the user threshold.
.It Li PMU Ta Li Button Ta pressed Ta
A button on a
.Xr adb 4
or
.Xr pmu 4
has been pressed.
.It Li PMU Ta Li keys Ta Ta
One of the keys on the
.Xr adb 4
keyboard has been pressed.
.It Li PMU Ta Li keys Ta brightness Ta
A brightness level change has been requested.
Direction is in the $notify variable.
.It Li PMU Ta Li keys Ta mute Ta
The mute key
.It Li PMU Ta Li keys Ta volume Ta
A volume level change has been requested.
Direction is in the $notify variable.
.It Li PMU Ta Li keys Ta eject Ta
An ejection has been requested.
.It Li PMU Ta Li lid Ta close Ta
The
.Xr pmc 4
device has detected the lid closing.
.It Li PMU Ta Li lid Ta open Ta
The
.Xr pmc 4
device has detected the lid openinging.
.It Li PMU Ta Li POWER Ta ACLINE Ta
The
.Xr pmc 4
device has deteted an AC line state ($notify=0x00 is offline, 0x01 is online).
.It Li PMU Ta Li USB Ta overvoltage Ta
An over-voltage condition on the power lines for the USB power pins.
.It Li PMU Ta Li USB Ta plugged Ta
A device has been plugged into a USB device.
.It Li PMU Ta Li USB Ta undervoltage Ta
An under-voltage condition on the power lines for the USB power pins.
.It Li PMU Ta Li USB Ta unplugged Ta
A device has been unplugged into a USB device.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li RCTL Ta Ta Ta
Events related to the
.Xr rctl 8
framework.
.It Li RCTL Ta Li rule Ta Li matched Ta
A rule with action specified as "devctl" was triggered.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li USB Ta Ta Ta
Events related to the USB subsystem.
.It Li USB Ta Li DEVICE Ta Li ATTACH Ta
USB device is attached to the system.
.It Li USB Ta Li DEVICE Ta Li DETACH Ta
USB device is detached to the system.
.It Li USB Ta Li INTERFACE Ta Li ATTACH Ta
USB interface is attached to a device.
.It Li USB Ta Li INTERFACE Ta Li DETACH Ta
USB interface is detached from a device.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li VFS Ta Ta Ta
Events from the vfs system.
.It Li VFS Ta Li FS Ta Ta
Events that change what is mounted to the system.
.It Li VFS Ta Li FS Ta Li MOUNT Ta
Notification of a filesystem is mounted for the first time.
.It Li VFS Ta Li FS Ta Li REMOUNT Ta
Notification of a filesystem is remounted (whether or not the options actually change).
.It Li VFS Ta Li FS Ta Li UNMOUNT Ta
Notification of a filesystem being unmounted.
.El
.Pp
.Bl -column "System" "Subsystem" "1234567" -compact
.Sy "System" Ta Sy "Subsystem" Ta Sy "Type" Ta Sy "Description"
.It Li ZFS Ta ZFS Ta Ta
Events about the ZFS subsystem.
See
.Xr zfsd 8
and
.Pa /etc/devd/zfs.conf
for details.
.El
.Pp
.\"
.\" End of tables
.\"
A link state change to UP on the interface
.Dq Li fxp0
would result in the following notify event:
.Bd -literal -offset indent
system=IFNET subsystem=fxp0 type=LINK_UP
.Ed
.Pp
An AC line state change to
.Dq offline
would result in the following event:
.Bd -literal -offset indent
system=ACPI subsystem=ACAD notify=0x00
.Ed
.Ss Comments
Comments may appear anywhere that whitespace may appear in a
configuration file.
To appeal to programmers of all kinds, they can
be written in C, C++, or shell/Perl constructs.
.Pp
C-style comments start with the two characters
.Ql /*
(slash, star) and end with
.Ql */
(star, slash).
Because they are completely delimited with these characters,
they can be used to comment only a portion of a line or to span
multiple lines.
.Pp
C-style comments cannot be nested.
For example, the following is
not valid because the entire comment ends with the first
.Ql */ :
.Bd -literal -offset indent
/* This is the start of a comment.
   This is still part of the comment.
/* This is an incorrect attempt at nesting a comment. */
   This is no longer in any comment. */
.Ed
.Pp
C++-style comments start with the two characters
.Ql //
(slash, slash) and continue to the end of the physical line.
They cannot be continued across multiple physical lines; to have
one logical comment span multiple lines, each line must use the
.Ql //
pair.
For example:
.Bd -literal -offset indent
// This is the start of a comment.  The next line
// is a new comment, even though it is logically
// part of the previous comment.
.Ed
.Ss Notes on Variable Expansion
To prevent issues with special shell characters, the following happens for each
variable
.Ic $foo .
.Bl -enum
.It
The characters
.Dq $'
are inserted.
.It
The string
.Dq $foo
is removed.
.It
The value of the
.Ic foo
variable is inserted into the buffer with all single quote characters
prefixed by a backslash.
.El
.Pp
See
.Xr sh 1
for what this construct means.
It is safe in all context, except one: inside single quotes.
If foo=meta and bar=var, then a rule like the following:
.Bd -literal -offset indent -compact
action "echo '$foo $bar'";
.Ed
will be presented to the shell via
.Xr system 3
as
.Bd -literal -offset indent -compact
echo '$'meta' $'var''
.Ed
which produces the following output:
.Bd -literal -offset indent -compact
$meta $var
.Ed
as its output.
This is an unanticipated result.
A future version of this software will change this behavior.
Users are discouraged from using single quotes inside
.Ic action
value without due care.
.Pp
The above should be written as
.Bd -literal -offset indent -compact
action "echo $foo' '$bar"
.Ed
to produce a single argument to echo.
Given the above expansion, juxtaposing bare variables with
single quote expressions will produce the right output,
regardless of the value of the variable.
.Sh FILES
.Bl -tag -width ".Pa /etc/devd.conf" -compact
.It Pa /etc/devd.conf
The
.Xr devd 8
configuration file.
.El
.Sh EXAMPLES
.Bd -literal
#
# This will catch link down events on the interfaces fxp0 and ath0
#
notify 0 {
	match "system"			"IFNET";
	match "subsystem"		"(fxp0|ath0)";
	match "type"			"LINK_DOWN";
	action "logger $subsystem is DOWN";
};

#
# Match lid open/close events
# These can be combined to a single event, by passing the
# value of $notify to the external script.
#
notify 0 {
	match "system"			"ACPI";
	match "subsystem"		"Lid";
	match "notify"			"0x00";
	action "logger Lid closed, we can sleep now!";
};

notify 0 {
	match "system"			"ACPI";
	match "subsystem"		"Lid";
	match "notify"			"0x01";
	action "logger Lid opened, the sleeper must awaken!";
};

#
# Match a USB device type
#
notify 0 {
	match "system"			"USB";
	match "subsystem"		"INTERFACE";
	match "type"			"ATTACH";
	match "intclass"		"0x0e";
	action "logger USB video device attached";
};

#
# Try to configure ath and iwn devices with pccard_ether
# as they are attached.
#
attach 0 {
        device-name "(ath|iwn)[0-9]+";
        action "/etc/pccard_ether $device-name start";
};

#
# Stop ath and iwn devices as they are detached from
# the system.
#
detach 0 {
        device-name "(ath|iwn)[0-9]+";
        action "/etc/pccard_ether $device-name stop";
};
.Ed
.Pp
The installed
.Pa /etc/devd.conf
has many additional examples.
.Sh BUGS
The variable expansion's interaction with single quotes is
suboptimal and surprising.
.Sh SEE ALSO
.Xr cam 4 ,
.Xr coretemp 4 ,
.Xr devfs 5 ,
.Xr re_format 7 ,
.Xr devd 8