Kernel driver max1668 ===================== Supported chips: * Maxim MAX1668, MAX1805 and MAX1989 Prefix: 'max1668' Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b, 0x4c, 0x4d, 0x4e Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX1668-MAX1989.pdf Author: David George <david.george@ska.ac.za> Description ----------- This driver implements support for the Maxim MAX1668, MAX1805 and MAX1989 chips. The three devices are very similar, but the MAX1805 has a reduced feature set; only two remote temperature inputs vs the four available on the other two ICs. The driver is able to distinguish between the devices and creates sysfs entries as follows: MAX1805, MAX1668 and MAX1989: temp1_input ro local (ambient) temperature temp1_max rw local temperature maximum threshold for alarm temp1_max_alarm ro local temperature maximum threshold alarm temp1_min rw local temperature minimum threshold for alarm temp1_min_alarm ro local temperature minimum threshold alarm temp2_input ro remote temperature 1 temp2_max rw remote temperature 1 maximum threshold for alarm temp2_max_alarm ro remote temperature 1 maximum threshold alarm temp2_min rw remote temperature 1 minimum threshold for alarm temp2_min_alarm ro remote temperature 1 minimum threshold alarm temp3_input ro remote temperature 2 temp3_max rw remote temperature 2 maximum threshold for alarm temp3_max_alarm ro remote temperature 2 maximum threshold alarm temp3_min rw remote temperature 2 minimum threshold for alarm temp3_min_alarm ro remote temperature 2 minimum threshold alarm MAX1668 and MAX1989 only: temp4_input ro remote temperature 3 temp4_max rw remote temperature 3 maximum threshold for alarm temp4_max_alarm ro remote temperature 3 maximum threshold alarm temp4_min rw remote temperature 3 minimum threshold for alarm temp4_min_alarm ro remote temperature 3 minimum threshold alarm temp5_input ro remote temperature 4 temp5_max rw remote temperature 4 maximum threshold for alarm temp5_max_alarm ro remote temperature 4 maximum threshold alarm temp5_min rw remote temperature 4 minimum threshold for alarm temp5_min_alarm ro remote temperature 4 minimum threshold alarm Module Parameters ----------------- * read_only: int Set to non-zero if you wish to prevent write access to alarm thresholds. |