Binding for Silicon Labs 570, 571, 598 and 599 programmable I2C clock generators. Reference This binding uses the common clock binding[1]. Details about the devices can be found in the data sheets[2][3]. [1] Documentation/devicetree/bindings/clock/clock-bindings.txt [2] Si570/571 Data Sheet http://www.silabs.com/Support%20Documents/TechnicalDocs/si570.pdf [3] Si598/599 Data Sheet http://www.silabs.com/Support%20Documents/TechnicalDocs/si598-99.pdf Required properties: - compatible: Shall be one of "silabs,si570", "silabs,si571", "silabs,si598", "silabs,si599" - reg: I2C device address. - #clock-cells: From common clock bindings: Shall be 0. - factory-fout: Factory set default frequency. This frequency is part specific. The correct frequency for the part used has to be provided in order to generate the correct output frequencies. For more details, please refer to the data sheet. - temperature-stability: Temperature stability of the device in PPM. Should be one of: 7, 20, 50 or 100. Optional properties: - clock-output-names: From common clock bindings. Recommended to be "si570". - clock-frequency: Output frequency to generate. This defines the output frequency set during boot. It can be reprogrammed during runtime through the common clock framework. Example: si570: clock-generator@5d { #clock-cells = <0>; compatible = "silabs,si570"; temperature-stability = <50>; reg = <0x5d>; factory-fout = <156250000>; }; |