Rockchip specific extensions to the Analogix Display Port PHY ------------------------------------ Required properties: - compatible : should be one of the following supported values: - "rockchip.rk3288-dp-phy" - clocks: from common clock binding: handle to dp clock. of memory mapped region. - clock-names: from common clock binding: Required elements: "24m" - #phy-cells : from the generic PHY bindings, must be 0; Example: grf: syscon@ff770000 { compatible = "rockchip,rk3288-grf", "syscon", "simple-mfd"; ... edp_phy: edp-phy { compatible = "rockchip,rk3288-dp-phy"; clocks = <&cru SCLK_EDP_24M>; clock-names = "24m"; #phy-cells = <0>; }; }; |