ST-Ericsson U300 apptimer Required properties: - compatible : should be "stericsson,u300-apptimer" - reg : Specifies base physical address and size of the registers. - interrupts : A list of 4 interrupts; one for each subtimer. These are, in order: OS (operating system), DD (device driver) both adopted for EPOC/Symbian with two specific IRQs for these tasks, then GP1 and GP2, which are general-purpose timers. Example: timer { compatible = "stericsson,u300-apptimer"; reg = <0xc0014000 0x1000>; interrupts = <24 25 26 27>; }; |