NVIDIA Tegra20/Tegra30 high speed (DMA based) UART controller driver. Required properties: - compatible : should be, "nvidia,tegra20-hsuart" for Tegra20, "nvidia,tegra30-hsuart" for Tegra30, "nvidia,tegra186-hsuart" for Tegra186, "nvidia,tegra194-hsuart" for Tegra194. - reg: Should contain UART controller registers location and length. - interrupts: Should contain UART controller interrupts. - clocks: Must contain one entry, for the module clock. See ../clocks/clock-bindings.txt for details. - resets : Must contain an entry for each entry in reset-names. See ../reset/reset.txt for details. - reset-names : Must include the following entries: - serial - dmas : Must contain an entry for each entry in dma-names. See ../dma/dma.txt for details. - dma-names : Must include the following entries: - rx - tx Optional properties: - nvidia,enable-modem-interrupt: Enable modem interrupts. Should be enable only if all 8 lines of UART controller are pinmuxed. - nvidia,adjust-baud-rates: List of entries providing percentage of baud rate adjustment within a range. Each entry contains sets of 3 values. Range low/high and adjusted rate. <range_low range_high adjusted_rate> When baud rate set on controller falls within the range mentioned in this field, baud rate will be adjusted by percentage mentioned here. Ex: <9600 115200 200> Increase baud rate by 2% when set baud rate falls within range 9600 to 115200 Baud Rate tolerance: Standard UART devices are expected to have tolerance for baud rate error by -4 to +4 %. All Tegra devices till Tegra210 had this support. However, Tegra186 chip has a known hardware issue. UART Rx baud rate tolerance level is 0% to +4% in 1-stop config. Otherwise, the received data will have corruption/invalid framing errors. Parker errata suggests adjusting baud rate to be higher than the deviations observed in Tx. Tx deviation of connected device can be captured over scope (or noted from its spec) for valid range and Tegra baud rate has to be set above actual Tx baud rate observed. To do this we use nvidia,adjust-baud-rates As an example, consider there is deviation observed in Tx for baud rates as listed below. 0 to 9600 has 1% deviation 9600 to 115200 2% deviation This slight deviation is expcted and Tegra UART is expected to handle it. Due to the issue stated above, baud rate on Tegra UART should be set equal to or above deviation observed for avoiding frame errors. Property should be set like this nvidia,adjust-baud-rates = <0 9600 100>, <9600 115200 200>; Example: serial@70006000 { compatible = "nvidia,tegra30-hsuart", "nvidia,tegra20-hsuart"; reg = <0x70006000 0x40>; reg-shift = <2>; interrupts = <0 36 0x04>; nvidia,enable-modem-interrupt; clocks = <&tegra_car 6>; resets = <&tegra_car 6>; reset-names = "serial"; dmas = <&apbdma 8>, <&apbdma 8>; dma-names = "rx", "tx"; nvidia,adjust-baud-rates = <1000000 4000000 136>; /* 1.36% shift */ }; |