* UniPhier Thermal bindings This describes the devicetree bindings for thermal monitor supported by PVT(Process, Voltage and Temperature) monitoring unit implemented on Socionext UniPhier SoCs. Required properties: - compatible : - "socionext,uniphier-pxs2-thermal" : For UniPhier PXs2 SoC - "socionext,uniphier-ld20-thermal" : For UniPhier LD20 SoC - "socionext,uniphier-pxs3-thermal" : For UniPhier PXs3 SoC - interrupts : IRQ for the temperature alarm - #thermal-sensor-cells : Should be 0. See ./thermal.txt for details. Optional properties: - socionext,tmod-calibration: A pair of calibrated values referred from PVT, in case that the values aren't set on SoC, like a reference board. Example: sysctrl@61840000 { compatible = "socionext,uniphier-ld20-sysctrl", "simple-mfd", "syscon"; reg = <0x61840000 0x10000>; ... pvtctl: pvtctl { compatible = "socionext,uniphier-ld20-thermal"; interrupts = <0 3 1>; #thermal-sensor-cells = <0>; }; ... }; thermal-zones { cpu_thermal { polling-delay-passive = <250>; /* 250ms */ polling-delay = <1000>; /* 1000ms */ thermal-sensors = <&pvtctl>; trips { cpu_crit: cpu_crit { temperature = <110000>; /* 110C */ hysteresis = <2000>; type = "critical"; }; cpu_alert: cpu_alert { temperature = <100000>; /* 100C */ hysteresis = <2000>; type = "passive"; }; }; cooling-maps { map0 { trip = <&cpu_alert>; cooling-device = <&cpu0 (-1) (-1)>; }; map1 { trip = <&cpu_alert>; cooling-device = <&cpu2 (-1) (-1)>; }; }; }; }; |