NVIDIA Tegra194 P2U binding Tegra194 has two PHY bricks namely HSIO (High Speed IO) and NVHS (NVIDIA High Speed) each interfacing with 12 and 8 P2U instances respectively. A P2U instance is a glue logic between Synopsys DesignWare Core PCIe IP's PIPE interface and PHY of HSIO/NVHS bricks. Each P2U instance represents one PCIe lane. Required properties: - compatible: For Tegra19x, must contain "nvidia,tegra194-p2u". - reg: Should be the physical address space and length of respective each P2U instance. - reg-names: Must include the entry "ctl". Required properties for PHY port node: - #phy-cells: Defined by generic PHY bindings. Must be 0. Refer to phy/phy-bindings.txt for the generic PHY binding properties. Example: p2u_hsio_0: phy@3e10000 { compatible = "nvidia,tegra194-p2u"; reg = <0x03e10000 0x10000>; reg-names = "ctl"; #phy-cells = <0>; }; |