# $NetBSD: VAX780,v 1.34 2023/02/06 13:13:05 tsutsui Exp $
#
# 11/780,750,730 machine description file
# 
# This machine description file is used to generate a NetBSD for the
# 11/780, 11/750 or 11/730 cpus.
#
# The machine description file can be customised for your specific
# machine to reduce the kernel size and improve its performance.
#
# For further information on compiling NetBSD kernels, see the config(8)
# man page.
#
# For further information on hardware support for this architecture, see
# the intro(4) man page.  For further information about kernel options
# for this architecture, see the options(4) man page.  For an explanation
# of each device driver in this file see the section 4 man page for the
# device.

include 	"arch/vax/conf/std.vax"

options 	INCLUDE_CONFIG_FILE	# embed config file in kernel binary

#ident 		"VAX780"

# Here are all different supported CPU types listed.
options 	VAX780
options 	VAX750
options 	VAX730

# Max users on system; this is just a hint
maxusers	8

# Kernel compiled-in symbolic debugger & system call tracer
makeoptions	DEBUG="-g"
options 	DDB
#options 	DDB_HISTORY_SIZE=100	# enable history editing in DDB
options 	KTRACE
#options 	DIAGNOSTIC
#options 	DEBUG
#options 	PMAPDEBUG
#options 	TRAPDEBUG
#options 	LOCKDEBUG

#options 	SCSIVERBOSE		# Verbose SCSI errors

# Networking options
#options 	GATEWAY		# packet forwarding
#options 	NTP		# NTP kernel support
options 	INET		# IP + ICMP + TCP + UDP
#options 	INET6		# IPV6
#options 	IPSEC		# IP security
#options 	IPSEC_DEBUG	# debug for IP security
#options 	MROUTING	# IP multicast routing
#options 	PIM		# Protocol Independent Multicast
#options 	NETATALK	# AppleTalk networking protocols
#options 	PPP_BSDCOMP	# BSD-Compress compression support for PPP
#options 	PPP_DEFLATE	# Deflate compression support for PPP
#options 	PPP_FILTER	# Active filter support for PPP (requires bpf)
options 	CPU_IN_CKSUM	# optimized checksum routine

#options 	ALTQ		# Manipulate network interfaces' output queues
#options 	ALTQ_BLUE	# Stochastic Fair Blue
#options 	ALTQ_CBQ	# Class-Based Queueing
#options 	ALTQ_CDNR	# Diffserv Traffic Conditioner
#options 	ALTQ_FIFOQ	# First-In First-Out Queue
#options 	ALTQ_FLOWVALVE	# RED/flow-valve (red-penalty-box)
#options 	ALTQ_HFSC	# Hierarchical Fair Service Curve
#options 	ALTQ_LOCALQ	# Local queueing discipline
#options 	ALTQ_PRIQ	# Priority Queueing
#options 	ALTQ_RED	# Random Early Detection
#options 	ALTQ_RIO	# RED with IN/OUT
#options 	ALTQ_WFQ	# Weighted Fair Queueing

# File systems
file-system 	FFS
#file-system 	LFS
file-system 	MFS
file-system 	NFS
file-system 	FDESC
file-system 	KERNFS
file-system 	NULLFS
#file-system 	OVERLAY		# overlay file system
file-system 	PROCFS
file-system 	UMAPFS
#file-system 	UNION
#file-system 	CD9660
file-system	PTYFS		# /dev/pts/N support
#file-system	TMPFS		# Efficient memory file-system
#file-system	UDF		# experimental - OSTA UDF CD/DVD file-system

# File system options
#options 	FFS_EI		# FFS Endian Independent support
#options 	FFS_NO_SNAPSHOT	# No FFS snapshot support
options 	QUOTA		# legacy UFS quotas
options 	QUOTA2		# new, in-filesystem UFS quotas
#options 	UFS_DIRHASH	# UFS Large Directory Hashing
options 	UFS_EXTATTR	# Extended attribute support for UFS1
#options 	WAPBL		# File system journaling support
#options 	NFSSERVER	# Network File System server
options 	NFS_BOOT_BOOTP,NFS_BOOT_DHCP	# Use bootp <> dhcp
options 	NFS_BOOT_BOOTPARAM	# Use the Sun way for netbooting.

# WS console uses VT100 terminal emulation
#options 	WSEMUL_VT100
#options 	WSDISPLAY_COMPAT_USL		# wsconscfg VT handling
#options 	WSDISPLAY_DEFAULTSCREENS=8
#options 	FONT_QVSS8x15

# System V shared memory & semaphores support.
options 	SYSVMSG
options 	SYSVSEM
options 	SYSVSHM

# Old compat stuff; needed to run 4.3BSD Reno programs.
# Note that if COMPAT_ULTRIX is set, you lose compatibility with
# 4.3BSD Reno programs and get Ultrix compatibility instead.
# (They cannot coexist).
include 	"conf/compat_netbsd09.config"
options 	COMPAT_VAX1K	# Must be present to run pre-1.4 binaries.
options 	COMPAT_ULTRIX	# DEC Ultrix binary compatibility.
#options 	NO_INSN_EMULATE	# CPU does not lack some hardware instructions.

options 	LKM

options 	USERCONF	# userconf(4) support
#options	PIPE_SOCKETPAIR	# smaller, but slower pipe(2)
options 	SYSCTL_INCLUDE_DESCR	# Include sysctl descriptions in kernel

# Alternate buffer queue strategies for better responsiveness under high
# disk I/O load.
#options 	BUFQ_READPRIO
#options 	BUFQ_PRIOCSCAN

# Kernel(s) to compile
config		netbsd root on ? type ?

mainbus0	at root

cpu*		at mainbus0

# All buses; from the beginning attached to mainbus.
sbi0		at mainbus0		# SBI, master bus on 11/780, 8600.
cmi0		at mainbus0		# 11/750 internal bus.
ubi0		at mainbus0		# 11/730 direct unibus
#bi0		at mainbus0		# VAX 8200
#vsbus0		at mainbus0		# All VAXstations
#nmi0		at mainbus0		# VAX 8800
#xmi0		at mainbus0		# VAX 6000
#uba0		at mainbus0		# All MicroVAX
#ze0		at mainbus0		# KA48, KA49, KA53
#le0		at mainbus0		# LANCE ethernet (MV3400)
#shac0		at mainbus0 		# DSSI controller

# NMI (internal bus) on VAX 88xx-series.
#cpu*		at nmi0 slot?		# 1-4 KA88 CPUs
#mem*		at nmi0 slot?
#bi*		at nmi0 slot?		# BI bus adapters

# XMI on VAX 6000 (and higher)
#cpu*		at xmi? node?		# 1-? VAX 6000 CPUs
#mem*		at xmi? node?
#bi*		at xmi? node?		# XMI-BI adapter

# Vsbus, the virtual VAXstation bus, and possible devices.
#le0		at vsbus0 csr 0x200e0000 # LANCE ethernet
#dz0		at vsbus0 csr 0x200a0000 # DC-367 DZ-11 lookalike ctlr
#dz0		at vsbus0 csr 0x25000000 # VS4000/90 and 4000/10x serial line
#si0		at vsbus0 csr 0x200c0080 # VS2000/3100 SCSI-ctlr
#si1		at vsbus0 csr 0x200c0180 # VS2000/3100 SCSI-ctlr
#asc0		at vsbus0 csr 0x200c0080 # VS4000/60 (or VLC) SCSI-ctlr
#asc0		at vsbus0 csr 0x26000080 # VS4000/90 and 4000/10x SCSI-ctlr
#smg0		at vsbus0 csr 0x200f0000 # Small monochrome display ctlr.
#gpx0		at vsbus0 csr 0x3c000000 # VS3100 GPX display option
#clr0		at vsbus0 csr 0x30000000 # 4- or 8-bitplans color graphics
#spx0		at vsbus0 csr 0x38000000 # Low Cost SPX on VS4000/90.
#lcg0		at vsbus0 csr 0x21801000 # VS4000/60 (or VLC) graphics
#tc0		at vsbus0 csr 0x36800000 # VS4000/60 or 90 TC adapter
#tcds*		at tc0 slot ? offset ?	 # TC dual SCSI controller
#asc*		at tcds? chip ?		 # PMAZB/C
#asc*		at tc? slot ? offset ?	 # PMAZ 
#le*		at tc? slot ? offset ?	 # PMAD

#hdc0		at vsbus0 csr 0x200c0000 # HDC9224 MFM/floppy ctlr
#rd*		at hdc0 drive?		# RD5x disks
#ry*		at hdc0 drive?		# RX floppies


# Devices connected at VAXBI
#cpu*		at bi? node?		# KA820/KA825 CPU
#mem*		at bi? node?		# Memory subsystems
#uba*		at bi? node?		# DWBUA BI-Unibus adapter
#ni*		at bi? node?		# DEBNA/DEBNT ethernet adapter
#kdb*		at bi? node?		# KDB50 MSCP disk ctlr

# CMI (VAX 11/750)
mem*		at cmi? tr?		# Memory subsystems
uba*		at cmi? tr?		# Unibus adapters
mba*		at cmi? tr?		# Massbus adapters

# UBI (VAX 11/730)
mem*		at ubi? tr?		# Memory subsystems
uba*		at ubi? tr?		# Unibus adapters

# SBI (VAX 11/780, VAX 8600)
mem*		at sbi? tr?		# Memory subsystems
uba*		at sbi? tr?		# Unibus adapters
mba*		at sbi? tr?		# Massbus adapters

# Devices on Massbus adapters
#hp*		at mba? drive?		# RM/RP disk drives

# Devices on Unibus/Qbus adapters
uda*		at uba?	csr 0172150	# UDA50/RQDX?
uda*		at uba?	csr 0160334
mtc*		at uba? csr 0174500	# Tape MSCP ctlr
ts0		at uba? csr 0172520	# TS11/TSV05 tape.
#qd0		at uba? csr 0177400	# 4- or 8-bitplans color graphics
#qv0		at uba? csr 0177400	# Monochrome graphics
de*		at uba? csr 0174510	# DELUA/DEUNA
#qe*		at uba? csr 0174440	# DEQNA/DELQA
#qe*		at uba? csr 0174460	# DEQNA/DELQA
#qt*		at uba? csr 0174440	# DELQA-PLUS in Turbo mode
#dhu*		at uba? csr 0160440	# DHU-11
#dmf*		at uba? csr 0160340	# DMF-32
#dz*		at uba? csr 0160100	# DZ-11
#dl*		at uba? csr 0176500	# DL-11
#rlc*		at uba? csr 0174400	# RL11/RLV11 controller
#rl*		at rlc? drive?		# RL01/RL02 disk drive
#rfc0		at uba? csr 0177170	# RX01/02 controller
#rf*		at rfc? drive?		# RX01/RX02 floppy disk drive

# MSCP devices
mscpbus*	at uda?
mscpbus*	at mtc?
#mscpbus*	at kdb?

ra*		at mscpbus? drive?	# MSCP disk
racd*		at mscpbus? drive?	# MSCP CD-ROM (RRD40)
rx*		at mscpbus? drive?	# MSCP floppy
mt*		at mscpbus? drive?	# MSCP tape

# SCSI devices
#scsibus*	at scsi?

#sd*		at scsibus? target? lun?
#st*		at scsibus? target? lun?
#cd*		at scsibus? target? lun?
#ch*		at scsibus? target? lun?
#ss*		at scsibus? target? lun?
#uk*		at scsibus? target? lun?

# VAXstation graphics support
#wsdisplay*	at smg0
#wsdisplay*	at gpx0
#wsdisplay*	at spx0
#wsdisplay*	at lcg0
#wsdisplay*	at clr0
#wsdisplay*	at qd0
#wsdisplay*	at qv0
#lkkbd0		at dz0 line 0
#wskbd*		at lkkbd? console ?
#lkms0		at dz0 line 1
#wsmouse*	at lkms?

#
# accept filters
#pseudo-device   accf_data		# "dataready" accept filter
#pseudo-device   accf_http		# "httpready" accept filter

pseudo-device	loop	
pseudo-device	pty			# pseudo-terminals
#pseudo-device	bpfilter
#pseudo-device	carp			# Common Address Redundancy Protocol
#pseudo-device	npf			# NPF packet filter
#pseudo-device	sl	
#pseudo-device	ppp	
#pseudo-device	pppoe			# PPP over Ethernet (RFC 2516)
#pseudo-device	tun	
#pseudo-device	tap			# virtual Ethernet
#pseudo-device	gre			# generic L3 over IP tunnel
#pseudo-device	gif			# IPv[46] over IPv[46] tunnel (RFC1933)
#pseudo-device	faith			# IPv[46] tcp relay translation i/f
#pseudo-device	stf			# 6to4 IPv6 over IPv4 encapsulation
#pseudo-device	vlan			# IEEE 802.1q encapsulation
#pseudo-device	bridge			# simple inter-network bridging
#pseudo-device	vether			# Virtual Ethernet for bridge
#pseudo-device	agr			# IEEE 802.3ad link aggregation
#pseudo-device	vnd	
#options 	VND_COMPRESSION		# compressed vnd(4)
#pseudo-device	ccd	
#pseudo-device	cgd			# cryptographic disk devices
#pseudo-device	raid			# RAIDframe disk driver
#options 	RAID_AUTOCONFIG		# auto-configuration of RAID components
# Options to enable various other RAIDframe RAID types.
# options	RF_INCLUDE_EVENODD=1
# options	RF_INCLUDE_RAID5_RS=1
# options	RF_INCLUDE_PARITYLOGGING=1
# options	RF_INCLUDE_CHAINDECLUSTER=1
# options	RF_INCLUDE_INTERDECLUSTER=1
# options 	RF_INCLUDE_PARITY_DECLUSTERING=1
# options	RF_INCLUDE_PARITY_DECLUSTERING_DS=1
#pseudo-device	fss			# file system snapshot device
#pseudo-device	leds			# control the leds on vaxstations.
pseudo-device	clockctl		# user control of clock subsystem
pseudo-device	ksyms			# /dev/ksyms
#pseudo-device	wsmux			# mouse & keyboard multiplexor

# Veriexec
# include "dev/veriexec.config"